<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20190208//EN"
       "JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.4" xml:lang="en">
 <front>
  <journal-meta>
   <journal-id journal-id-type="publisher-id">Medical Radiology and radiation safety</journal-id>
   <journal-title-group>
    <journal-title xml:lang="en">Medical Radiology and radiation safety</journal-title>
    <trans-title-group xml:lang="ru">
     <trans-title>Медицинская радиология и радиационная безопасность</trans-title>
    </trans-title-group>
   </journal-title-group>
   <issn publication-format="print">1024-6177</issn>
   <issn publication-format="online">2618-9615</issn>
  </journal-meta>
  <article-meta>
   <article-id pub-id-type="publisher-id">37197</article-id>
   <article-id pub-id-type="doi">10.12737/1024-6177-2020-65-2-50-56</article-id>
   <article-categories>
    <subj-group subj-group-type="toc-heading" xml:lang="ru">
     <subject>Радиационная физика, техника и дозиметрия</subject>
    </subj-group>
    <subj-group subj-group-type="toc-heading" xml:lang="en">
     <subject>Radiation physics, technology and dosimetry</subject>
    </subj-group>
    <subj-group>
     <subject>Радиационная физика, техника и дозиметрия</subject>
    </subj-group>
   </article-categories>
   <title-group>
    <article-title xml:lang="en">Development of Chemical Samples Preparation Method to Reduce the Lower Limit of Absorbed Dose Assessment by Electron Paramagnetic Resonance Spectrometry</article-title>
    <trans-title-group xml:lang="ru">
     <trans-title>Разработка метода химической пробоподготовки для снижения нижнего предела оценки поглощенной дозы методом спектрометрии электронного парамагнитного резонанса</trans-title>
    </trans-title-group>
   </title-group>
   <contrib-group content-type="authors">
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Пантелькин</surname>
       <given-names>В. П.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Pantelkin</surname>
       <given-names>V. P.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-1"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Журавлева</surname>
       <given-names>Валентина Е.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Zhuravleva</surname>
       <given-names>Valentina E.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-2"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Цовьянов</surname>
       <given-names>Александр Г.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Tsoviyanov</surname>
       <given-names>Aleksandr G.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-3"/>
    </contrib>
   </contrib-group>
   <aff-alternatives id="aff-1">
    <aff>
     <institution xml:lang="ru">Федеральный медицинский биофизический центр им. А.И. Бурназяна ФМБА России</institution>
     <city>Москва</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">A.I. Burnasyan Federal Medical Biophysical Center of FMBA</institution>
     <city>Moscow</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-2">
    <aff>
     <institution xml:lang="ru">ФГБУ ГНЦ ФМБЦ им. А.И. Бурназяна ФМБА России</institution>
     <city>Москва</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">State Research Center Burnasyan Federal Medical Biophysical Center, Federal Medical Biological Agency</institution>
     <city>Moscow</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-3">
    <aff>
     <institution xml:lang="ru">ФГБУ ГНЦ ФМБЦ им. А.И. Бурназяна ФМБА России</institution>
     <city>Москва</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">State Research Center Burnasyan Federal Medical Biophysical Center, Federal Medical Biological Agency</institution>
     <city>Moscow</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <volume>65</volume>
   <issue>2</issue>
   <fpage>50</fpage>
   <lpage>56</lpage>
   <self-uri xlink:href="https://naukaru.ru/en/nauka/article/37197/view">https://naukaru.ru/en/nauka/article/37197/view</self-uri>
   <abstract xml:lang="ru">
    <p>Цель: Разработка метода химической пробоподготовки для снижения нижнего предела оценки поглощенной дозы методом ЭПР-спектрометрии. &#13;
Материал и методы: Для проведения работ по изучению влияния химической обработки образцов костного материала в органических растворителях на их ЭПР-спектры было подготовлено необходимое число образцов костей. Они были подвергнуты первичной обработке для отделения костей от остатков мягкой биологической ткани, затем была выделена плотная кость и проведено ее обезжиривание. Далее была проведена серия параллельных опытов по дополнительной химической обработке костных материалов в растворах трех органических восстановителей (гидразин гидрат, диэтитилентриамин и этилендиамин) для уменьшения величины нативного сигнала при проведении работ по реконструкции поглощенных доз методом ЭПР-спектрометрии. Запись спектров ЭПР производилась на спектрометре ELEXSYS E500 фирмы Bruker, снабженном высокодобротным цилиндрическим резонатором SHQE. Облучение образцов проводилось на рентгеновской биологической установке РУБ РУСТ-М1.&#13;
Результаты: Для уменьшения нижнего предела измерения поглощенной дозы и повышения надежности получаемых оценок значений поглощенной дозы с помощью метода ЭПР требуется уменьшить нативную составляющую ЭПР сигнала, не затрагивая, по возможности, радиационную составляющую сигнала ЭПР. Для достижения такого эффекта была предложена химическая обработка образцов костного материала в растворах аминов, которые воздействуют на коллагеновые соединения, присутствующие в костях и ответственные за появление нативного сигнала в спектре ЭПР. После химической обработки образцов костного материала при 30 °С в течение 30 мин в растворе разных аминов произошло существенное уменьшение амплитуды нативного сигнала, которое составило: 4 для гидразин гидрата, 3,3 для диэтитилентриамина и 2,1 для этилендиамина. Для образцов костного материала, которые подвергались предложенной химической обработке в гидразин гидрате, удается уверенно определить амплитуду радиационного сигнала со значением 2–3 Гр против минимальных значений доз 6–8 Гр для образцов костного материала, которые не подвергались химической обработке.&#13;
Выводы: Было установлено, что при проведении химической обработки происходит существенное уменьшение нативного сигнала в спектре ЭПР костных материалов, уменьшение же радиационного сигнала при этом незначительно. Сравнение результатов обработки костных материалов в трех органических восстановителях показало, что лучшие результаты дает применение гидразин гидрата при температуре 30 °С в течение 30 мин.</p>
   </abstract>
   <trans-abstract xml:lang="en">
    <p>Purpose: Development of a method of chemical sample preparation to reduce the lower limit of the absorbed dose estimation by EPR spectrometry. &#13;
Material and methods: The required number of bone samples was prepared to study the effect of chemical treatment of bone material samples in organic solvents on their EPR spectra. They were subjected to primary treatment to separate the bones from the remains of soft biological tissue, then a dense bone was isolated and its defatting was carried out. Further, a series of parallel experiments on chemical treatment of bone materials in solutions of three organic reducing agents (hydrazine hydrate, ethylenediamine and diethylenetriamine) were done to reduce the magnitude of the native signal when carrying out works on reconstruction of absorbed doses using EPR spectroscopy. Recording of EPR spectra was performed on the ELEXSYS E500 Bruker spectrometer equipped with a high-q cylindrical resonator SHQE. Irradiation of the samples was carried out on the X-ray biological unit RUB RUST-M1.&#13;
Results: To reduce the lower limit of detection of the absorbed dose and improve the reliability of the assessment of the absorbed dose using the EPR method, it is required to reduce the native component of the EPR signal without affecting, if possible, the radiation component of the EPR signal. To achieve this effect, a chemical treatment in solutions of amines was proposed, which affect the collagen compounds that present in the bones and which are responsible for the appearance of a native signal in the EPR spectrum. After chemical treatment of bone material samples at 30°C for 30 minutes in a solution of different amines, there was a significant decrease in the amplitude of the native signal, which was: 4 for hydrazine hydrate, 3.3 for diethylenetriamine and 2.1 for ethylenediamine. For bone material samples that were subjected to the proposed chemical treatment in hydrazine hydrate, it is possible to confidently determine the amplitude of the radiation signal by a value of 2–3 Gy against the minimum dose values of 6–8 Gy for bone material samples that were not chemically treated.&#13;
Conclusion: It was found that during the chemical treatment there is a significant reduction of the native signal in the spectra of EPR of bone materials, the decrease of the radiation signal at the same time was slightly. Comparison of the results of treatment of bone materials in three organic reducing agents showed that the best results are obtained by the use of hydrazine hydrate at a temperature of 30°C for 30 minutes.</p>
   </trans-abstract>
   <kwd-group xml:lang="ru">
    <kwd>электронный парамагнитный резонанс</kwd>
    <kwd>радиационный сигнал</kwd>
    <kwd>нативный сигнал</kwd>
    <kwd>поглощенная доза</kwd>
    <kwd>кость</kwd>
    <kwd>химическая обработка</kwd>
   </kwd-group>
   <kwd-group xml:lang="en">
    <kwd>Electron Paramagnetic Resonance</kwd>
    <kwd>radiation signal</kwd>
    <kwd>native signal</kwd>
    <kwd>absorbed dose</kwd>
    <kwd>bone</kwd>
    <kwd>chemical treatment</kwd>
   </kwd-group>
  </article-meta>
 </front>
 <body>
  <p></p>
 </body>
 <back>
  <ref-list>
   <ref id="B1">
    <label>1.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Местные лучевые поражения. В кн.: Радиационная медицина. Руководство для врачей-исследователей и организаторов здравоохранения. Под ред. Л.А. Ильина. Т. 2. - М.: ИздАт, 2001, С.161-202.</mixed-citation>
     <mixed-citation xml:lang="en">Local Radiation Injuries in: Radiation Medicine. A Guide for Medical Researchers and Health Care Organizers. Ed. by L. A. Ilyin. Vol. 2. - Moscow. IzdAt, 2001:161-202. (in Russ.).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B2">
    <label>2.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Барабанова А.В., Баранов А.Е., Бушманов А.Ю., Гуськова А.К. Радиационные поражения человека. Избранные клинические лекции, методическое пособие. Под ред. А.Ю. Бушманова, В.Д. Ревы. - Москва. 2007.</mixed-citation>
     <mixed-citation xml:lang="en">Barabanova AV, Baranov AE, Bushmanov AYu, Guskova AK. Radiation damage to humans. Selected clinical lectures, methodological guide. Eds. by AYu Bushmanov, VD Reva. Moscow, 2007. (in Russ.).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B3">
    <label>3.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Надежина Н.М., Галстян И.А., Сачков А.В., Малиновская И.А. Перспективы диагностики и лечения местных лучевых поражений. Медицинская радиология и радиационная безопасность. 2004:49(4):21-8. [Nadezhina NM, Galstyan IA, Sachkov AV, Malinovskaya IA. Prospects for the diagnosis and treatment of local radiation injuries. Medical Radiology and Radiation Safety. 2004:49(4):21-8. (in Russ.)].</mixed-citation>
     <mixed-citation xml:lang="en">Nadezhina NM, Galstyan IA, Sachkov AV, Malinovskaya IA. Prospects for the diagnosis and treatment of local radiation injuries. Medical Radiology and Radiation Safety. 2004:49(4):21-8. (in Russ.).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B4">
    <label>4.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Галстян И.А., Илевич Ю.Р, Клещенко Е.Д. и др. Возможности ретроспективного определения дозы при лучевых поражениях. Медицинская радиология и радиационная безопасность. 2004;49(5):5-13.</mixed-citation>
     <mixed-citation xml:lang="en">Galstyan IA, Ilevich YuR, Kleshchenko ED, et al. Possibilities of retrospective dose estimation in radiation injuries. Medical Radiology and Radiation Safety. 2004;49(5):5-13. (in Russ.).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B5">
    <label>5.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Надежина Н.М., Барабанова А.В., Галстян И.А. Трудности диагностики и лечения пострадавших от воздействия потерянных источников ионизирующего излучения. Медицинская радиология и радиационная безопасность. 2005;50(4):15-20.</mixed-citation>
     <mixed-citation xml:lang="en">Nadezhina NM, Barabanova AV, Galstyan IA. Difficulties in diagnosis and treatment of victims of exposure to lost sources of ionizing radiation. Medical Radiology and Radiation Safety. 2005;50(4):15-20. (in Russ.)].</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B6">
    <label>6.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Барабанова А.В. Местные лучевые поражения кожи. Медицинская радиология и радиационная безопасность. 2010;55(5):79-84.</mixed-citation>
     <mixed-citation xml:lang="en">Barabanova AV. Local radiation lesions of the skin. Medical Radiology and Radiation Safety. 2010;55(5):79-84. (in Russ.)].</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B7">
    <label>7.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Козицина А.Н., Иванова А.В., Глазырина Ю.А., Цмокалюк А.Н., Ивойлова А.В., Петров А.С. ЭПР-спектроскопия, электрохимические и комбинированные методы анализа. Учеб.-метод. пособие. Под. ред. Ю.А. Глазыриной. Екатеринбург: Изд-во Урал. ун-та, 2018. 60 с.</mixed-citation>
     <mixed-citation xml:lang="en">Kozitsyna AN, Ivanova AV, Glazyrina YA, Tsmokalyuk AN, Ivoylova AV, Petrov AS. EPR spectroscopy, electrochemical and combined methods of analysis. Training manual. Ed. by AYu Glazyrina. Ekaterinburg: publishing House of Ural University, 2018. 60 p. (in Russ.).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B8">
    <label>8.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Ikeya M. New applications of electron spin resonance: dating, dosimetry and microscopy. Singapore; River Edge: World Scientific, 1993. 500 p.</mixed-citation>
     <mixed-citation xml:lang="en">Ikeya M. New applications of electron spin resonance: dating, dosimetry and microscopy. Singapore; River Edge: World Scientific, 1993. 500 p.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B9">
    <label>9.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Samoylov AS, Bushmanov AY, Galstyan IA, Nadezhina NA, Pantelkin VP, Aksenenko AV, et al. Local radiolesion in X-ray inspection specialists. Radiation Protection Dosimetry. 2016;171(1):117-20.</mixed-citation>
     <mixed-citation xml:lang="en">Samoylov AS, Bushmanov AY, Galstyan IA, Nadezhina NA, Pantelkin VP, Aksenenko AV, et al. Local radiolesion in X-ray inspection specialists. Radiation Protection Dosimetry. 2016;171(1):117-20.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B10">
    <label>10.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">The Radiological Accident in Lia, Georgia. Vienna: International Atomic Energy Agency, 2014.</mixed-citation>
     <mixed-citation xml:lang="en">The Radiological Accident in Lia, Georgia. Vienna: International Atomic Energy Agency, 2014.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B11">
    <label>11.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Fattibene P, Callence F. EPR dosimetry with tooth enamel: A review. Appl Radiat and Isotopes. 2010;68(11):2033-116.</mixed-citation>
     <mixed-citation xml:lang="en">Fattibene P, Callence F. EPR dosimetry with tooth enamel: A review. Appl Radiat and Isotopes. 2010;68(11):2033-116.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B12">
    <label>12.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Скрипник Д.Г. Влияние физико-химической обработки эмали зуба человека на сигнал ЭПР. Автореф. дисс. к.х.н. Обнинск, 2004, 23 с.</mixed-citation>
     <mixed-citation xml:lang="en">Skripnik DG. Effect of physical and chemical treatment of human tooth enamel on the EPR signal. Abstract of thesis for the degree of PhD Chem, Obninsk, 2004, 23 p. (in Russ.)].</mixed-citation>
    </citation-alternatives>
   </ref>
  </ref-list>
 </back>
</article>