<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20190208//EN"
       "JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.4" xml:lang="en">
 <front>
  <journal-meta>
   <journal-id journal-id-type="publisher-id">Medical Radiology and radiation safety</journal-id>
   <journal-title-group>
    <journal-title xml:lang="en">Medical Radiology and radiation safety</journal-title>
    <trans-title-group xml:lang="ru">
     <trans-title>Медицинская радиология и радиационная безопасность</trans-title>
    </trans-title-group>
   </journal-title-group>
   <issn publication-format="print">1024-6177</issn>
   <issn publication-format="online">2618-9615</issn>
  </journal-meta>
  <article-meta>
   <article-id pub-id-type="publisher-id">26792</article-id>
   <article-id pub-id-type="doi">10.12737/article_5c55fb630f2228.33688535</article-id>
   <article-categories>
    <subj-group subj-group-type="toc-heading" xml:lang="ru">
     <subject>В помощь практическому врачу</subject>
    </subj-group>
    <subj-group subj-group-type="toc-heading" xml:lang="en">
     <subject>Medical practice issue</subject>
    </subj-group>
    <subj-group>
     <subject>В помощь практическому врачу</subject>
    </subj-group>
   </article-categories>
   <title-group>
    <article-title xml:lang="en">Slot-Radiography. New Possibilities of Radiation Diagnostics</article-title>
    <trans-title-group xml:lang="ru">
     <trans-title>Слот-рентгенография. Новые возможности лучевой диагностики</trans-title>
    </trans-title-group>
   </title-group>
   <contrib-group content-type="authors">
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Левитов</surname>
       <given-names>А. А.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Levitov</surname>
       <given-names>A. A.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-1"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Дога</surname>
       <given-names>В. И.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Doga</surname>
       <given-names>V. I.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-2"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Белицкая</surname>
       <given-names>Г. С.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Belitskaya</surname>
       <given-names>G. S.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-3"/>
    </contrib>
   </contrib-group>
   <aff-alternatives id="aff-1">
    <aff>
     <institution xml:lang="ru">Федеральный медицинский биофизический центр им. А.И. Бурназяна ФМБА России</institution>
     <city>Москва</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">A.I. Burnasyan Federal Medical Biophysical Center of FMBA</institution>
     <city>Moscow</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-2">
    <aff>
     <institution xml:lang="ru">Федеральный медицинский биофизический центр им. А.И. Бурназяна ФМБА России</institution>
     <city>Москва</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">A.I. Burnasyan Federal Medical Biophysical Center of FMBA</institution>
     <city>Moscow</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-3">
    <aff>
     <institution xml:lang="ru">Федеральный медицинский биофизический центр им. А.И. Бурназяна ФМБА России</institution>
     <city>Москва</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">A.I. Burnasyan Federal Medical Biophysical Center of FMBA</institution>
     <city>Moscow</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <volume>64</volume>
   <issue>1</issue>
   <fpage>74</fpage>
   <lpage>79</lpage>
   <self-uri xlink:href="https://naukaru.ru/en/nauka/article/26792/view">https://naukaru.ru/en/nauka/article/26792/view</self-uri>
   <abstract xml:lang="ru">
    <p>Слот (щелевая)-рентгенография – это рентгенологическое исследование, при котором за один проход рентгеновской трубки над пациентом выполняется планарная рентгенография узким направленным пучком с дальнейшей компьютерной сшивкой полученных изображений на рабочей станции. Применение инновационных методик захвата и обработки изображений в сочетании с широкоформатным плоскопанельным детектором позволяет получать изображения большой протяженности, от одной до нескольких анатомических областей. При проведении исследования рентгеновская трубка и плоскопанельный детектор движутся в параллельных плоскостях друг относительно друга с постоянной скоростью вдоль  оси тела. Таким образом достигается минимальное искажение полученного изображения и возможность получения обработанных изображений без визуальных дефектов. Это дает возможность проводить более точную диагностику патологических изменений. Слот-рентгенография может проводиться в положении пациента как стоя, так и лежа в зависимости от области интереса и поставленных задач. Возможно выполнение снимков как в прямой, так и в боковой проекции без потери качества.&#13;
Слот-рентгенография эффективно применяется для диагностики патологических изменений суставов и позвоночника, в том числе сколиозов, укорочений конечностей, нестабильности сегментов позвоночника, патологии вен нижних конечностей, а также как метод оценки качества проведенного лечения. Данная методика характеризуется удобством и безопасностью для пациента, минимальными временнЫми затратами и низкой лучевой нагрузкой.&#13;
Применение данной методики значительно повышает информативность рентгенологического обследования, выводит его на качественно новый уровень, предоставляя врачу широкий спектр диагностических возможностей.</p>
   </abstract>
   <trans-abstract xml:lang="en">
    <p>Slot-radiography is an x-ray examination in which a two-dimensional radiography with a straight beam and further computer stitching of the images obtained on the workstation during a single-pass of x-ray tube over a patient. The application of innovative techniques for image acquisition and processing in combination with a large-area flat panel detector (FPD) makes it possible to produce long-view images from one to several anatomical regions. During the investigation, the x-ray tube and the FPD move simultaneously at a constant speed in parallel relative to one another with the longitudinal axis of the body. Thus, it makes possible to obtain images with little distortion and processed images without visual defects. And this allows conducting more accurate diagnosis of pathological changes. Slot-radiography can be performed both in the patient’s standing position and lying down depending on the region of interest and tasks. It is possible to obtain images in both a frontal and a lateral projection without loss of quality.&#13;
Slot-radiography is effectively used to diagnose pathological changes in joints and spine, including scoliosis, limb shortening, segmental spinal instability, pathology of lower limb veins, and also as a method for assessing the quality of the treatment. This technique is characterized by safety and convenience for the patient: minimal time costs and low radiation exposure.&#13;
The application of this technique significantly increases the informative value of the x-ray examination, brings it to a qualitatively new level, providing a physician with a wide range of diagnostic possibilities.</p>
   </trans-abstract>
   <kwd-group xml:lang="ru">
    <kwd>слот-рентгенография</kwd>
    <kwd>цифровая рентгенография</kwd>
    <kwd>лучевая диагностика</kwd>
    <kwd>плоскопанельные детекторы</kwd>
    <kwd>протезирование суставов</kwd>
   </kwd-group>
   <kwd-group xml:lang="en">
    <kwd>slot radiography</kwd>
    <kwd>digital radiography</kwd>
    <kwd>flat panel detector</kwd>
    <kwd>orthopedic surgery</kwd>
   </kwd-group>
  </article-meta>
 </front>
 <body>
  <p></p>
 </body>
 <back>
  <ref-list>
   <ref id="B1">
    <label>1.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Левитов А.А., Краснюк В.И., Дога В.И. Цифровой линейный томосинтез: новые возможности лучевой диагностики // Мед. радиол. и радиац. безопасность. 2014. Т. 59. № 3. С. 32-38.</mixed-citation>
     <mixed-citation xml:lang="en">Levitov AA, Krasnuk VI, Doga VI. Linear digital tomosynthesis: new opportunities for radiation diagnostics. Medical Radiology and Radiation Safety. 2014;59(3):32-8. (Russian).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B2">
    <label>2.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Левитов А.А., Краснюк В.И., Ситникова Е.В., Дунаев А.П. Эффективность цифрового линейного томосинтеза в определении очаговых образований легких, подозрительных на метастатическое поражение, в сравнении с цифровой рентгенографией у больных раком молочной железы // Мед. радиол. и радиац. безопасность. 2013. Т. 57. № 2. С. 46-52.</mixed-citation>
     <mixed-citation xml:lang="en">Levitov AA, Krasnyuk VI, Sitnikova EV. The effectiveness of x-ray linear digital tomosynthesis in visualization of focal lesions in lungs, suspected metastases, comparing with digital radiography in patients with breast cancer. Medical Radiology and Radiation Safety. 2013;57(2):46-52. (Russian).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B3">
    <label>3.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Kazuya Goto. Clinical experiences with slot radiography using Sonialvision safire II, and its utility − lower limb region // Medical Now. 2009. № 65. P. 23-26.</mixed-citation>
     <mixed-citation xml:lang="en">Kazuya Goto. Clinical experiences with slot radiography using Sonialvision safire II, and its utility − lower limb region. Medical Now.  2009(65):23-6.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B4">
    <label>4.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Shigeji Ichikawa. Experience of using slot radiography - experimental use for lower extremity venography // Medical Now. 2009. № 66.</mixed-citation>
     <mixed-citation xml:lang="en">Shigeji Ichikawa. Experience of using slot radiography - experimental use for lower extremity venography. Medical Now. 2009(66).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B5">
    <label>5.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Yasuhide Koshika, Hogaku Gen, Seiji Konishi et al. Investigation of the reliability of spinopelvic parameter measurements - Intraobserver And Interobserver Reliability. https://www.shimadzu.com/med/literature/fluoro/k25cur0000003yfx-att/od0gjn00000077uh.pdf, 37</mixed-citation>
     <mixed-citation xml:lang="en">Yasuhide Koshika, Hogaku Gen, Seiji Konishi, Yoshio Sakuma, Yutaka Kono, Yasushi Nagahama, Nobutaka Sentsui. Investigation of the reliability of spinopelvic parameter measurements - intraobserver and interobserver reliability. https://www.shimadzu.com/med/literature/fluoro/k25cur0000003yfx-att/od0gjn00000077uh.pdf, 37</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B6">
    <label>6.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Yukio Amamiya. Using the Sonialvision G4 for orthopedics - utility of the slot advance application // Medical Now. 2014. № 76.</mixed-citation>
     <mixed-citation xml:lang="en">Yukio Amamiya. Using the Sonialvision G4 for orthopedics - utility of the slot advance application. Medical Now. 2014(76).</mixed-citation>
    </citation-alternatives>
   </ref>
  </ref-list>
 </back>
</article>
