Moscow, Russian Federation
Murmansk, Russian Federation
Murmansk, Russian Federation
Moscow, Russian Federation
Moscow, Russian Federation
Murmansk, Russian Federation
Russian Federation
GRNTI 76.03 Медико-биологические дисциплины
GRNTI 76.33 Гигиена и эпидемиология
OKSO 14.04.02 Ядерные физика и технологии
OKSO 31.06.2001 Клиническая медицина
OKSO 32.08.12 Эпидемиология
OKSO 31.08.08 Радиология
BBK 51 Социальная гигиена и организация здравоохранения. Гигиена. Эпидемиология
BBK 534 Общая диагностика
TBK 5708 Гигиена и санитария. Эпидемиология. Медицинская экология
TBK 5712 Медицинская биология. Гистология
TBK 5734 Медицинская радиология и рентгенология
TBK 6212 Радиоактивные элементы и изотопы. Радиохимия
Purpose: Validation of requirements to the hardware and software of pre-shift psychophysiological monitoring and assessment of effectiveness of use of technology of the vibraimage at pre-shift psychophysiological control of personnel of radiation and nuclear dangerous enterprises and objects of the State Atomic Energy Corporation ROSATOM. Material and methods: Pre-shift psychophysiological control of employees of Elektrochimpribor plant (20 people) and the Northwest Center for Radioactive Waste Management “SevRAO” , a Branch of FSUE RosRAO, Zaozersk of Murmansk region (18 workers of facilities for management of spent nuclear fuel and radioactive waste). Pre-shift psychophysiological monitoring was carried out within 3 months. During the research measurement of arterial blood pressure, assessment of health, activity and mood was taken. The psychophysiological condition was estimated according to innovative technology of the vibraimage with the use of the Vibrastaff program. Results: Reliability improvement of a human factor is one of the main ways of improving radiation and nuclear safety of the facilities and objects of the State Atomic Energy Corporation ROSATOM. It demands improving methods and means of psychophysiological providing. First of all methods, tools and criteria of pre-shift psychophysiological control. The developed requirements to the hardware and software of pre-shift psychophysiological monitoring and innovative technology of assessment of parameters of the vibraimage allow quickly (within 1 minute) to receive the decision on the admission / not the admission to work. Its practical use gives the chance, according to pre-shift psychophysiological control in due time, to accept organizational, medical and other administrative decisions for improving radiation and nuclear safety of the enterprises and objects of the State Atomic Energy Corporation ROSATOM.
vibraimages, pre-shift medical examinations, pre-shift psychophysiological control, psychophysiological adaptation, psychophysiological “price” of work performance, radiation safety, human factor
1. Bobrov AF, BushmanovAYu, Sedin VI, ShcheblanovVYu. System assessment of the results of psychophysiological control.Medicine of Extreme Situations.2015;(3):13-9. Russian.
2. Minkin VA. Vibraimage. Saint Petersburg: Renome; 2007. Russian.
3. Program for monitoring psychophysiological state of the operator of VibraStaff [Internet]. Saint Petersburg: Multiprofile facility ELSIS; 2018 [cited 2018 Feb 1]. Available from: http://psymaker.com/downloads/VIManualRuVS.pdf. Russian.